NPSH and cavitation: what they are and how to avoid them
Noise, vibration and wrecked impellers: cavitation is a pump's number-one enemy. Here is how to avoid it.
Schnelle Lieferung weltweit
Cavitation is the forming and collapsing of vapour bubbles inside the pump. It causes noise (like gravel being sucked in), vibration, loss of performance and, over time, impeller erosion. The key to avoiding it is NPSH.
What NPSH is
NPSH (Net Positive Suction Head) is the suction pressure available above the liquid's vapour pressure. It splits into NPSH available (the system's) and NPSH required (the pump's, on the curve).
The golden rule
To run safely: NPSH available ≥ NPSH required + margin (typically 0.5–1 m). If available drops below required, the pump cavitates.
How to raise NPSH available
- Lower the pump relative to the liquid level (or give it a flooded suction).
- Make the suction pipe shorter and wider, with fewer bends and valves.
- Lower the liquid temperature (less vapour pressure).
Choose a pump with low NPSH required
Well-designed pumps have a low required NPSH. Compare models in our Grundfos catalogue or start from pumps for industry and process, where suction is often critical.