Dati principali
- Portata nominale68,5 m³/h
- Prevalenza nominale13,1 m
- Potenza P24 kW
- Tensione nominale380-500 V
- Temperatura liquido max120 °C
- Tipo di attaccoDIN
Descrizione
Single stage double pump with spiral pump body in inline design. The suction and discharge ports have the same diameter. The pump and the motor are directly connected to each other. The double pump has two pump heads arranged in parallel. The pumps are designed according to the top-pull-out principle, i.e. the pump head (motor, head piece and impeller) can be easily removed for maintenance or servicing, while the pump casing remains in the piping. Each pump head is equipped with an unbalanced ru
Dati tecnici
Dati elettrici
| Frequenza | 50 Hz |
|---|---|
| Convertitore di frequenza | Integrato |
| Grado di protezione | IP55 |
| Indice di efficienza minima | 0,54 |
| Fasi | 3 |
| Potenza P2 | 4 kW |
| Corrente nominale | 7.60-6,20 A |
| Tensione nominale | 380-500 V |
Dimensioni e peso
| Peso lordo | 210 kg |
|---|---|
| Altezza | 140 mm |
| Lunghezza | 500 mm |
| Interasse | 500 mm |
| Peso | 210 kg |
Altri dati
| Temperatura ambiente | -20 ... 50 °C |
|---|---|
| Pressione nominale attacco | PN 16 |
| Materiale girante | Ghisa |
| Temperatura ambiente max | 50 °C |
| Temperatura liquido max | 120 °C |
| Pressione di esercizio max | 16 bar |
| Pressione max di esercizio | 16 bar |
| Temperatura liquido min | 0 °C |
| Codice motore | 93057189 |
| Portata nominale | 68,5 m³/h |
| Portata nominale | 68,5 m³/h |
| Prevalenza nominale | 13,1 m |
| Tipo di attacco | DIN |
| Materiale corpo pompa | Ghisa |
| Tipo pompa | TPE |
| Tenuta meccanica | BAQE |
Altri codici
| EAN / GTIN | 5712607035204 |
|---|
Curva di prestazione