Grundfos KWM
KWM pumps are Grundfos submersible mixed-flow pumps designed for vertical and submerged installation; the mixed-flow impeller is designed for the duty point of the pump.
Read more
KWM pumps are Grundfos submersible mixed-flow pumps designed for vertical and submerged installation; the mixed-flow impeller is designed for the duty point of the pump.
KPL, KPG and KWM pumps are fitted with 11-700 kW motors (4- to 20-pole, depending on the motor size) and are made of resistant materials, such as cast iron and stainless steel, which ensure high durability in storm- and wastewater applications: flood and stormwater control, drainage and irrigation of large quantities of water, raw-water intake, transfer of liquids in large-scale municipal sewage treatment plants, circulation of large quantities of water and fish farming.
Key data
- Motor power: 11 to 700 kW (KPL, KPG and KWM range)
- Frequency: 50 Hz, DIN
- Pumped liquids: pH 4 to 10, liquid temperature 0 to 40 °C
- Motor: insulation class F (155 °C), enclosure class IP68, service factor 1.1
- Starts: up to 15 per hour up to 90 kW, 10 per hour above 90 kW
Key features
- Compact design for easy handling and installation; easy maintenance
- Double mechanical shaft seal system in silicon carbide, in a cartridge
- Watertight cable entry with dual sealing system; two moisture switches
- Self-cleaning hydraulics reduce the risk of jamming and clogging
- Pt100 sensors in windings and bearings
-
Grundfos
KWM 600.37.4 T 50.310 H 40
Code 99265849
- Nominal flow: 979.2 m³/h
- Nominal head: 9.9 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.45.4 T 50.320 H 40
Code 99265855
- Nominal flow: 975.6 m³/h
- Nominal head: 12 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.55.4 T 50.330 H 40
Code 99301463
- Nominal flow: 1,065.6 m³/h
- Nominal head: 12.8 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.55.4 T 50.340 H 40
Code 99301464
- Nominal flow: 1,173.6 m³/h
- Nominal head: 13.2 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.65.4 T 50.340 H 40
Code 99301469
- Nominal flow: 1,173.6 m³/h
- Nominal head: 13.2 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.65.4 T 50.350 H 40
Code 99301470
- Nominal flow: 1,288.8 m³/h
- Nominal head: 13.6 m
- Rated voltage: 400 V
-
Grundfos
KWM 700.75.4 T 50.360 H 40
Code 99301471
- Nominal flow: 1,321.2 m³/h
- Nominal head: 14.8 m
- Rated voltage: 400 V
-
Grundfos
KWM 700.90.4 T 50.375 H 40
Code 99301475
- Nominal flow: 1,569.6 m³/h
- Nominal head: 15.6 m
- Rated voltage: 400 V
-
Grundfos
KWM 700.110.4 T 50.390 H 40
Code 99301479
- Nominal flow: 1,699.2 m³/h
- Nominal head: 18.2 m
- Rated voltage: 400 V
-
Grundfos
KWM 800.90.6 T 50.480 H 40
Code 99301480
- Nominal flow: 2,340 m³/h
- Nominal head: 10.1 m
- Rated voltage: 400 V
-
Grundfos
KWM 800.110.6 T 50.480 H 40
Code 99301483
- Nominal flow: 2,340 m³/h
- Nominal head: 10.1 m
- Rated voltage: 400 V
-
Grundfos
KWM 800.110.6 T 50.510 H 40
Code 99301484
- Nominal flow: 2,664 m³/h
- Nominal head: 12.4 m
- Rated voltage: 400 V
-
Grundfos
KWM 800.132.6 T 50.510 H 40
Code 99301487
- Nominal flow: 2,664 m³/h
- Nominal head: 12.4 m
- Rated voltage: 400 V
-
Grundfos
KWM 800.160.6 T 50.540 H 40
Code 99301491
- Nominal flow: 2,988 m³/h
- Nominal head: 14.7 m
- Rated voltage: 400 V
-
Grundfos
KWM 900.132.6 T 50.470 H 40
Code 99301492
- Nominal flow: 2,588.4 m³/h
- Nominal head: 15.5 m
- Rated voltage: 400 V
-
Grundfos
KWM 1000.220.6 T 50.580 H 40
Code 99301496
- Nominal flow: 4,032 m³/h
- Nominal head: 15.4 m
- Rated voltage: 400 V
-
Grundfos
KWM 1000.250.6 T 50.600 H 40
Code 99301502
- Nominal flow: 41,040 m³/h
- Nominal head: 18.5 m
- Rated voltage: 400 V
-
Grundfos
KWM 1000.300.6 T 50.615 H 40
Code 99301507
- Nominal flow: 4,500 m³/h
- Nominal head: 19.3 m
- Rated voltage: 400 V
-
Grundfos
KWM 1000.350.6 T 50.630 H 40
Code 99301512
- Nominal flow: 4,860 m³/h
- Nominal head: 20.1 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.45.4 T 50.315 M 40
Code 99301513
- Nominal flow: 1,234.8 m³/h
- Nominal head: 9 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.55.4 T 50.325 M 40
Code 99301517
- Nominal flow: 1,299.6 m³/h
- Nominal head: 11.7 m
- Rated voltage: 400 V
-
Grundfos
KWM 600.65.4 T 50.335 M 40
Code 99301521
- Nominal flow: 1,454.4 m³/h
- Nominal head: 13.3 m
- Rated voltage: 400 V
-
Grundfos
KWM 700.45.6 T 50.410 M 40
Code 99301522
- Nominal flow: 1,764 m³/h
- Nominal head: 6.7 m
- Rated voltage: 400 V
-
Grundfos
KWM 700.55.6 T 50.410 M 40
Code 99301527
- Nominal flow: 1,764 m³/h
- Nominal head: 6.7 m
- Rated voltage: 400 V
Code not listed? Send us the code